Product Name: HT-FX760 Laser Gas Analyzer
器特點
Instrument Features

a. Highlighted OLED active-luminescent display, with clear and intuitive display;

b. TDLAS (Tunable semiconductor laser absorption spectrum) technology is used to measure without background gas cross interference;

c. The multiple reflection optical path design provides a longer effective optical path, thereby improving the measurement accuracy and precision;

d. Equipped with a polytetrafluoroethylene filtration device, it filters out impurities while maintaining the optical signal transmittance, and is easy to clean and replace;

e. The mirror heating function prevents the adhesion of viscous substances and keeps the mirror surface clean;

f. Automatic temperature and pressure compensation could eliminate the impact of environment temperature and pressure changes on the measurement accuracy;

g. 40 thousand pieces of historical data can be stored automatically, enabling user to read historical data freely;

h. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range;

i. Flameproof design has high safety factor;

j. The structure is compact, with excellent reliability and stability, fast response speed, and is capable of real-time reflection of the measured gas concentration;

k. In explosion-proof places, the menu can be set by isolated magnetic pen, which is easy to operate on site;

l. Standard DN65 PN1.0 flange is installed by butt joint, which is quick and convenient to install.

術參數
Technical Parameters

l Test Principle: TDLAS (Tunable semiconductive laser absorption spectrum)

l Test Composition: O2, CO, NH3, CO2, CH4, C2H2, C3H8

l Test Range: 0-100%

(Note: Every set of analyzer can only test the concentration of one kind of gas, composition and test range are customizable)

l Display Method: 128×64 dot matrix OLED

l Resolution: 0.01%

l Light Path Length: 1.5m

l Linear Error: ≤1%.FS

l Zero Drift: ≤1%.FS/ year

l Range Drift: ≤1%.FS/ half year

l Response Time: T90<10s

l Maintenance Cycle:≤2 times/ year, clean optical window

l Calibration Cycle: ≤2 times/ year

l Input Port: 2 ways of 4-20mA input (temperature and pressure compensation)

l Output Port: 2 way of 4-20mA output (Oxygen concentration and transmittance, maximum load resistance<1KΩ)

1 way of programmable alarm relay output (Dry contact type, maximum load 220V/2A)

l Communication Output: RS485

l Power Supply: DC24V±10%,<20VA

l Ambient Temperature: -20°C~+60°C

l Operation Environment Temperature: Gauge: -20°C~+50°C

Probe:-20°C~+80°C

l Environment Humidity: <90%RH, non-condensing

l Sampling Mode: Diffusion

l Operation Pressure: 0.8~1.4bar, maximum pressure for probe 5bar

l Calibration Gas Path Connection: NPT 1/8 internal thread

l EX Grade: Ex dbⅡC T6 Gb

l Dust Proof Grade: Ex tb ⅢC T80℃ Db

l Certification Number:CNEx23.0412X

l Protection Level: IP66

l Sensor Service Life:>5 years (under normal conditions of use)

l Instrument Weight: Net weight 16.8Kg

l Installation: Plug-in, standardDN65 PN1.0 flange installation 

用場合
Application Scenarioses

It is applied in gas concentration detection and analysis in bioreactors, composting (processing), gas generation, oxygen content measurement, automatic inert sealing systems, solvent tanks, chemical/pharmaceutical reactions, methane/landfill gas oxygen monitoring, chemical, pharmaceutical, steel, environmental protection, food industries, etc.

貨須知
Ordering Instructions