Product Name: HT-LE230 Hydrogen Analyzer
器特點
Instrument Features

a. Menu can be switched between Chinese and English and the operation is intuitive and convenient;

b. 128×64 dot matrix liquid crystal display is clear to see;

c. Original imported thermal conductance sensor has high measurement accuracy, long calibration cycle and long service life, etc.;

d. When power is off, the service life of the sensor will not be influenced;

e. Temperature compensation function could eliminate the impact of environmental temperature changes on the measurement accuracy;

f. Power is supplied in a wide range to reduce fluctuation from public power supply;

g. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range;

h. The analyzer carries one way of programmable 4-20mA analog output, one way of 0-5V analog output and 2 ways of programmable alarm output in dry contact type;

i. RS232 (default) or RS485 digital communication port can be selected according to clients’ requirement, to realize unidirectional or bidirectional communication with computer or other digital communication facilities.

術參數
Technical Parameters

l Measurement Principle: Thermal conductance

l Display Mode: 128×64 dot matrix LCD

l Measurement Range: 0.01%~2%/30%/50%/99.99% H2(range selectable)   

l Measurement Accuracy: ≤±1.0%FS   

l Maximum Resolution: 0.01%

l Repeatability: ≤±1.0%FS

l Response Time: T90≤60S

l Output Port: 4-20mA.DC (Non-isolated output, load resistance<1KΩ)

0-5V.DC(Non-isolated output, load resistance>10KΩ)

2 ways of programmable alarm output (Dry contact type, maximum load 220V/2A)

l Communication Mode: RS232 (default) or RS485

l Power Supply: AC220V±10% 50/60Hz

l Environment Temperature: -10℃~+50℃

l Storage Environment Humidity: <90%RH, non-condensing

l Operation Environment Humidity: <100%RH, non-condensing

l Sample Gas Temperature: 0℃~50℃

l Sampling Mode: Gas in

l Gas Inlet Pressure: Relative pressure ±5kPa, stable pressure,control the pressure within the recommended limits to make sure the flow is within 400~600mL/min (air flowmeter) or 1.4~2.1L/min (H2flowmeter)

l Gas Outlet Pressure: Free venting (under safe conditions)

l Background Gas: No corrosive gas (except for He)

l Size: 100mm×100mm×108mm (H×W×D)

l Installation Hole Size: 92mm×92mm (H×W)

l Sensor Service Life: >5 years (under normal conditions of use)

l Gas Circuit Port: NPT 1/8 internal thread

l Installation Method: Embedded mounting (instrument)

Wall mounting (probe)