Product Name: HT-LH366 Humidity Analyzer
器特點
Instrument Features

l Measurement Principle: Electric capacity

l Display Mode: 4 digit high-light LED, display resolution 0.1%

l Measurement Range: Volume absolute humidity: 0~40.0%VOL

             Relative humidity: 0~100%RH

             High-temperature dew point: -20℃~+100℃

(Default: Volume absolute humidity. Only one mode can be displayed and cannot be changed once leaving the factory. Please indicate the display mode you need when ordering.)

l Measurement Accuracy: ≤±1.5%FS comprehensive accuracy, high-temperature dew point ≤±0.5℃

l Repeatability: ≤±1.0%FS

l Response Time: T90≤30S

l Output Port: 4-20mA.DC (Non-isolated output, load resistance<1KΩ)

              2 ways of programmable alarm output (Dry contact type, maximum load 220VAC/2A)

l Communication Mode: RS485 (default) or RS232

l Power Supply: AC220V±10% 50/60Hz, power dissipation< 80VA (heat tracing equipped), 20VA (heat tracing not equipped)

l Operation Temperature: Gauge head: -10℃~+50℃, probe: 0~170℃

l Heating Type: Electric heating (optional), temperature 0~150℃

l Protection Level: Probe material: 316F, gauge head: IP65

l Probe Length: Normal length 0.5m、1.0m、1.2m, other length is customizable (≤1.8m)

l Sensor Service Life: >24 months (under normal conditions of use)

l Instrument Weight: Net weight 8.2Kg (1.0m)

l Installation Plug-in, standard DN65 flanged mounting

術參數
Technical Parameters

a. Integrated design makes it easy to install and is able to reduce the impact on measurement value from outer interference;

b. Original imported sensor has high measurement accuracy, strong anti-interference capacity and rapid response speed, and it is high-temperature resistant and weak-acid resistant;

c. Unique heating tracing design could prevent the condensation of sulfide and water vapor effectively;

d. The instrument supports multi-fractional linear calibration to satisfy the accurate test among the entire test range;

e. The menu lock function could prevent mis-operation, which may change instrument parameters and affect its performance;

f. Automatic temperature compensation function could eliminate the impact of environmental temperature changes on the measurement value;

g. Two-stage filter could filter dust and acid fluid effectively;

h. The protection level of the gauge head is IP65 and is suitable for outdoor severe environment

i. The probe is made of 316L and is strongly corrosive-resistant. Other material can be customized or spraying the probe with corrosive-resistant coat for severe application;

j. It is easy to operate and maintain, and has a long service life;

k. Display mode in volume absolute humidity, relative humidity and high-temperature dew point are available.(Display mode can not be changed after leaving the factory, please indicate the display mode you need when ordering.)

用場合
Application Scenarioses

It is applied to the humidity measurement of desulfurization equipment, ultra-low emission, VOC and other occasions in gas on-line continuous monitoring system CEMS, and it can also be used for humidity control in industries of wood, building materials, papermaking, chemical industry, pharmaceutical industry, tobacco, printing and dyeing, etc.

Note:If the environment is of low temperature, high humidity and high dust, we would provide you reasonable solutions on flue gas humidity.

貨須知
Ordering Instructions

l Sample gas temperature

l Probe length

l Duty parameter (corrosivity, air speed, dust content, etc.)

Contact Number

028-85044052/053