Product Name: HT-SY80-EX Oxygen Analysis System
器特點
Instrument Features

a. The segment code display mode is clear and intuitive, and the operation of the instrument is easy and convenient;

b. The original imported fuel cell sensor has a high measurement accuracy, rapid response speed, long calibration cycle and strong anti-interference capability, etc

c. The menu lock function could prevent mis-operation, which may change instrument parameters and affect its performance;

d. In explosion-proof occasions, the menu can be set by isolated-type magnetic pen, which is convenient for on-site operation;

e. Automatic temperature compensation could eliminate the impact of environment temperature changes on the measured value;

f. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range.

g. Its explosion-proof level is Exd IIC T6.

術參數
Technical Parameters

l Measurement Principle: Fuel cell

l Display Mode: Segment code display

l Measurement Range: 0~1000PPm, 0~1%/25%/100% O2

              (different ranges are selectable: trace or normal)

l Measurement Accuracy: 0~1000PPm/1%/25%/100%≤±1%FS

              0~100PPm≤±2%FS

              0~10PPm≤±5%FS

l Repeatability: ≤±1.0%FS

l Response Time: T90≤60S

l Output Port: 4-20mA.DC (Non-isolated output, load resistance<1KΩ) 

1 way of programmable alarm output (Dry contact type, maximum load 220VAC/2A)

l Communication Mode: RS485  

l Power Supply: DC24V±10%, 200mA

l Environment Temperature: -10℃~+50℃

l Storage Environment Humidity:<90%RH, non-condensing

l Operation Environment Humidity:<100%RH, non-condensing

l Sample Gas Temperature: 0℃~40℃

l Sampling Mode: Gas in

l Gas Inlet Pressure: Relative pressure ±5kPa, stable pressure (control the pressure within the recommended limits to make sure the flow is within 400~600mL/min)

l Gas Outlet Pressure: Free venting (under safe conditions)

l Sample Gas Composition: No strong corrosive gas

l Size: 250mm×160.5mm×92.5mm (H×W×D)

l Explosion-Proof Level: Exd IIC T6 Gb

l Certificate Number: CNEx19.1804X

l Sensor Service Life: >36 months (under normal conditions of use)

l Installation Method: Wall mounting